AM370APM PARAMETER
Item
Function
Test conditions and requirements
Rated voltage
2V
3V
4.5V
Operating voltage
1.8V—3V
2.5V—4V
4V—5.5V
Rated current
415mA
170mA
110mA
Load current
900mA
420mA
250mA
Fill with 50KPa gas into 100CC bottle to test the working current of the product.
Air flow
1.5L—3.5L
Pressure
>80Kpa
Noise
52.5dB
51dB
51.5dB
Fill with 50KPa gas into 100CC bottle to test the product's working noise.(Ambient noise ≤ 45dB)
Service life
Carbon brush
>350H
Metal brush
>100H
Operating environment
Temperature: ≤ 50 C
Humidity: 75 %
Fluid Usage
Air
Weight
57.2g
59g